SBEM Explained

SBEM Calculations are a method of showing compliance with Part L: Conservation of Fuel & Power, of Building Regulations for non-dwellings otherwise known as commercial property. The calculations seek to demonstrate that the actual building concerned performs better, in terms of energy efficiency, than a notional building which conforms to the current standards set by Building Regulations. The notional building is the same shape and orientation as the actual building and the activities performed within each individual zone are also identical, the only things that do differ are the percentage glazing used within the calculations and the mechanical and electrical installations such as heating, cooling, ventilation, hot water generation and lighting.


The notional building will produce a Target Emission Rate (TER) in KgCO2/m² per annum and as this suggests this is a target which the actual building must not exceed in order to demonstrate compliance with Part L of the Building Regulations. The actual building will produce a Building Emission Rate (BER), if BER ≤ TER then the building concerned complies with regulations.
There are a couple of other hoops that must be jumped through in order to satisfy Building Regulations such as limiting u-value standards W/m².K for all external elements, efficiency of heat sources, power consumed through mechanical ventilation,  lighting and air tightness of the building.

Producing a building which merely complies to minimum standards will almost certainly not be enough to give a successful outcome of any SBEM Calculation, Building Regulations 2010 have sought to vastly improve energy performance of new buildings and minimum standards must be largely improved upon in order to achieve a positive outcome. Whether it is improved u-values, air tightness or lighting efficiencies which are implemented, a situation of robbing Peter to pay Paul is often the situation which we at L2 Energy see on a daily basis.

On many occasions these days buildings will not pass without the introduction of renewable energy such as Photo-voltaics, Air or Ground Source Heat Pumps, Solar Thermal or Combined Heat and Power (CHP) Plant, all of these can be modelled into the calculation tool to identify the most appropriate solution for a given site and client.

L2 Energy Consulting have an enormous wealth of experience in achieving compliance for a whole manner of differing building types from schools, hospitals and clubhouses to 10 storey office blocks, flagship industrial facilities and large hotel developments, whatever the scheme we will find a solution.


Visit http://www.l2energy.co.uk/ for a full list of our services or email enquiries@L2energy.co.uk with any queries you may have. L2 Energy Consulting are here to help.

Wednesday, 1 February 2012

SBEM completed on 10 Storey London Office Block

L2 Energy recently completed SBEM Calculations to meet Part L Building Regulations Compliance for CO2 Emissions on a 10 Storey London Office Block. This complex building was an initial challenge but with the use of one of the most sophisticated energy modelling packages we overcame the complex design to demonstrate compliance and achieve much needed Breeam credits.

Another SBEM Completed for new South Coast Gym

L2 Energy have successfully completed the initial SBEM Calculations for a proposed new gym in Lymington, Hampshire. We advised the client of the necessary U-values needed and on suitably energy efficient mechanical and electrical installations in order to achieve Building Regulation Compliance.

If you need guidance on a similar project or in fact on any commercial enterprise please do get in contact by using the following email in the first instance. enquiries@L2energy.co.uk or visit our website at www.L2energy.co.uk

SBEM for 34 Unit Industrial Estate in Poole

L2 Energy Consulting have successfully completed 'As Designed' SBEM Calculations for a new 34 Unit Industrial Estate in Poole, Dorset.