Friday, 29 July 2011
Another SBEM Complete
L2 Energy complete As Designed SBEM Calculations on new Industrial Estate in Poole, Dorset. It is increasingly more difficult to achieve a Pass on the small units on the park but with some forward thinking, a cost effective solution can be found without the use of photovoltaics.
Friday, 22 July 2011
New Appointment
L2 Energy have been appointed to provide SBEM Calculations and EPCs for a new 10 Unit Industrial Estate in Poole, Dorset.
Wednesday, 20 July 2011
L2 Energy launch SBEM Tender-Risk Service
Our SBEM Tender-Risk service is designed to help Contractors bridge the information gap at tender stage at a reduced cost see http://www.l2energy.co.uk/sbem-tenderrisk.html for more details.
Monday, 18 July 2011
Decision Made!!
L2 Energy Consulting have decided to go for a complete revamp of the website www.L2energy.co.uk all we need to do now is find a forward thinking web-designer to improve the look and feel of the site and to much improve the bounce rate.
Saturday, 16 July 2011
SBEM Calculations for new college development
A prestigious new function hall for a college in Kent is now ready for building control submission following the completion of the SBEM Calculations performed by L2 Energy Consulting.
Thursday, 14 April 2011
SBEM Calculations completed on Leisure Centre Extension
L2 Energy Consulting have just completed the SBEM Calculations on the long awaited extension to a Christchurch Leisure Centre in Dorset. Work is expected to start on site later this year.
Tuesday, 8 March 2011
The Lighting makes all the difference to SBEM Calculation
A new office building in County Durham was destined for the 'Green Wash' treatment with the introduction of Photovoltaics as the SBEM Calculation was not allowing compliance with Building Regulations Part L 2010. With costs spiraling the client was on the verge of shelving the project, however L2 Energy Consulting were determined to come up with an alternative solution to help the client and prevent the need for inclusion of any renewable technology on the scheme. SBEM Calculations are extremely sensitive to the efficiencies of the Building Services and in particular the lighting design. After investigating the situation further we advised the client that with the use of the right light fittings with a high Light Output Ratio (LOR) in excess of 80% and with the utilization of T5 lamps with a high luminous flux a Lighting Efficacy of 75 or more can be achieved. This can have a huge difference the Building Emission Rate (BER) in an SBEM Calculation and with the introduction of photometric and movement sensors for switching a further improvement can be made.
To learn more about SBEM or other services provided visit www.L2energy.co.uk or contact Jason Cook on 01202 485235 or via email on jason.cook@L2energy.co.uk
To learn more about SBEM or other services provided visit www.L2energy.co.uk or contact Jason Cook on 01202 485235 or via email on jason.cook@L2energy.co.uk
Thursday, 27 January 2011
Proposed Office Development passes SBEM at first attempt.
With the help of L2 Energy Consulting a new head-office development in Oxfordshire due to start on site in early Spring 2011 has sailed through its 'Design Stage' SBEM Calculations. With the use of two high efficiency heat pumps and an energy efficient lighting design the property was more than 12% more efficient than the current Building Regulations require under Part L2 Conservation of Heat & Power. For more information on our full service offering visit www.L2energy.co.uk
SBEM Calculations
L2 Energy Consulting have been appointed to perform the SBEM Calculations on the proposed extension to Christchurch Junior School in Dorset. For a full list of the services we provide visit http://www.l2energy.co.uk/
Subscribe to: